Technical data
Technical data:
power rating | 10 W/m |
supply power | ~ 230 V |
cable thickness | 4,5 mm |
power cable width | 11 mm |
heating element | variable resistance polymer |
outer layer | chemical and biological compounds resistant |
protective screen | + |
certificates | driking water pipelines |
installation | surface/internal |
protection level | Ex |
Product details
Product details:
TV ESLR 10 AF is a self-regulating cable resistance-variable. Designed for external de-icing systems. The cable protects drinking water systems against freezing. TV ESLR 10 AF is certified to use it inside the drinking water pipelines. It can also be used to maintain temperature process (eg. in food industry). In the construction of the cable we used a special heating polymer. Which is capable of varying heat output dependent on ambient temperature changes. The outer shell is made of natural material and resistant to chemical and biological compounds. It’s possible to trim the cable to any length, which for many applications is the ideal solution eg. heating short lengths of pipes, armatures or control and measurement.
Thanks to power self-regulation technology and the special protective coating, the cable can be used to protect:
- drinking water pipeline
- industrial technological pipelines
- drains
- structural elements of machines and equipment, sewage pipes and septic tanks
TV ELSR 10 AF complies the European standard IEC 60800 1998